AC
Circuit Specifications
|
| Initial Clamping Level . . . . . . . . . .
. . . |
200 Volts |
| UL 1449 Surge Protection Rating . . . |
330 Volts |
| Protection Modes . . . . . . . . . . . . .
. . . . . |
Line to Neutral, Line to Ground, Neutral to
Ground |
| Line Voltage . . . . . . . . . . . . . . .
. . . . . . . |
120 VAC 50/60 Hz |
| Maximum Current Rating . . . . . . . . . .
|
15 Amperes (1800 Watts) |
| EMI / RFI Noise Filtration . . . . . . . .
. . |
50 db (99.7%) from 100 Khz to 1 Mhz |
| Response Time . . . . . . . . . . . . . .
. . . . . . |
Instantaneous, ( less than 1 Nanosecond ) |
| Single Pulse Energy Dissipation . . . . |
672 Joules |
| Peak Impulse Current . . . . . . . . . . .
. . |
40,000 Amperes |
Catastrophic Surge Fuse . . . . . . . . .
. .
|
Shuts off power automatically, preventing
damage from
massive surges, even lightning |
Thermal Fuse . . . . . . . . . . . . . . .
. . . . . .
|
In the event of extended overvoltage, shuts
off power
to connected equipment, preventing damage |
| Antenna
/ Additional TV Coaxial Circuit Specifications
|
| Connections . . . . . . . . . . . . . . .
. . . . . . . |
Female "F" Connectors |
| Clamping Level . . . . . . . . . . . . . .
. . . . . . |
0.7 Volts |
| Catastrophic Surge Current . . . . . . . .
|
Prevents damage from massive surges, even
lightning |
Satellite
Circuit Specifications
|
| Connections . . . . . . . . . . . . . . .
. . . . . |
Female "F" Connectors |
| Clamping Level . . . . . . . . . . . . . .
. . . . . |
27 Volts |
| Catastrophic Surge Current . . . . . . . .
|
Prevents damage from massive surges, even
lightning |
|
Telecommunications
Circuit Specifications
|
| Connections . . . . . . . . . . . . . . .
. . . . . . . . |
RJ-11 / 45 |
| Clamping Level . . . . . . . . . . . . . .
. . . . . . |
240 Volts |
| Capacitance . . . . . . . . . . . . . . .
. . . . . . . . |
50 pf (approx.) |
| Suppression Modes . . . . . . . . . . . .
. . . . . |
Metallic and longitudinal |
| Pins Protected . . . . . . . . . . . . . .
. . . . . . . |
2 wire / 1 pair, pins 4, 5 |
Fuseless . . . . . . . . . . . . . . . . .
. . . . . . . . .
|
Automatically disconnects from the phone line
under
surge and sneak current conditions. Automatically
reconnects after the fault condition disappears. |
| Under
/ Over Voltage |
Under . . . . . . . . . . . . . . . . . .
. . . . . . . . . .
|
Shuts off at 90 Volts or less, automatically
resets when
voltage returns to normal |
| Over . . . . . . . . . . . . . . . . . . .
. . . . . . . . . .
|
Shuts off at 134 Volts or more, automatically
resets when
voltage returns to normal |